| Electronics Residues Testing Methods |
|
|
| Written by Terry Munson | |||
| Friday, 31 October 2008 19:00 | |||
An analysis of four common methods starts with FTIR.Eric W. Weisstein explains In its simplest form, a Fourier transform spectrometer consists of two mirrors located at a right angle to each other and oriented perpendicularly, with a beamsplitter placed at the vertex of the right angle and oriented at a 45° angle relative to the two mirrors (Figure 1). Radiation incident on the beamsplitter from one of the two “ports” is then divided into two parts, each of which propagates down one of the two arms and is reflected off one of the mirrors. ![]() The two beams are then recombined and transmitted out the other port. When the position of one mirror is continuously varied along the axis of the corresponding arm, an interference pattern is swept out as the two phase-shifted beams interfere with each other. FTIR provides specific information about chemical bonding and molecular structures, making it useful for analyzing organic materials and certain inorganic materials. Chemical bonds vibrate at characteristic frequencies, and when exposed to IR radiation, they absorb the radiation at frequencies that match their vibration modes. Measuring radiation absorption as a function of frequency produces a spectrum that can be used to identify functional groups and compounds. ![]() Applications and limitations include identifying the molecular structure of organic compounds for contamination analysis; identification of organic particles, powders, films, and liquids (material identification); and the large (20,000 item) library of materials to match material signatures, which permits observations on the pure material and aged materials (for changes). The assessment of unknown visible residues on electronics involves looking at samples from the top of soldermask, laminate and metallization. When samples are analyzed, they tend to include these other materials. The analysis shows the presence of combined materials, and no separation is done using this technique; and while it can identify a family, it cannot quantify the residue amount. Residue assessment will reveal that a white flaky or gooey material around a solder joint is a flux, but that’s where it stops. With 70% of the industry using no-clean fluxes, this provides slightly more information than in known pretesting. Terry Munson is with Foresite Inc. (residues.com); This e-mail address is being protected from spambots. You need JavaScript enabled to view it . This column appears monthly.
|
Columns
| European RoHS Enforcement Explained |
A series of workshops next month on compliance with RoHS and other directives will help US companies looking to break into the European market. |
| Read more... |
| Believing Foxconn Means Suspending Belief |
The Foxconn makeover is in full swing, with the latest this piece from the New York Times that supposes that the world's largest ODM is worried that Apple -- yes, Apple -- might be bringing it down: |
| Read more... |
Features
| Managing Your ESD Program |
The processes are as important as the tools. |
| Read more... |
| SMT Reflow Oven-to-Oven Repeatability |
How to adjust an oven so a single recipe will work across multiple ovens for an individual product. |
| Read more... |
Products
Inventec Releases SnBiAg Solder Paste
Tin-bismuth-silver solder paste for SMT assembly has silver content of >1% for improved mechanical reliability and thermal cycling. Melting point is around 139°C. Offers good soldering yield for...
Tin-bismuth-silver solder paste for SMT assembly has silver content of >1% for improved mechanical reliability and thermal cycling. Melting point is around 139°C. Offers good soldering yield for...