| Correlating 2-D and 3-D SPI |
|
|
| Written by Rita Mohanty, Ph.D. | |||
| Saturday, 31 May 2008 19:00 | |||
As pads get smaller, the correlation between the various area measurements weakens.Solder paste area measurement is highly influenced by the technique used to collect the solder paste deposit image. Since solder paste deposits are rarely shaped like perfect cylinders or cubes, area measurements based on 2-D images typically will be slightly larger than area measurements based on 3-D images. Likewise, since 3-D area measurements represent an area of a cross-section of the deposit, 3-D area measurements typically will be smaller than 2-D measurements. Could they be correlated in a sound statistical manner that will provide a reliable prediction model? 2-D inspection techniques are capable of providing transfer area information only, while 3-D inspection techniques provide additional information such as height and volume transfer. While the volumetric transfer is considered to be more informative, there is not a well-known supply of data comparing and contrasting the two techniques. Our study attempted to correlate the area transfer data obtained from a true 2-D measurement technique with the area measurement obtained from a 3-D height map through a series of controlled experiments. In addition, we attempted to correlate area measurement with volume measurement to provide a tool to determine when area measurement can be used to monitor and control the printing process. Experimental methodology. The test vehicle was a 10" x 8" x 0.062", four-layer FR-4 board with ENIG surface finish. It included a range of commercially available components and packages: BGA 225, BGA 256, PLCC 28, QFP 160, QFP 208, R 0603, R 1206 and R 1201. An MPM Accela printer was used to conduct all printing and in-printer 2-D area inspection. CyberOptics SE300 SPI system was used to inspect the boards offline to provide 3-D area map, height and volume data. Four boards were printed using a 0.003" Efab stencil and Type 4 solder paste. To reduce print direction noise, both forward and reverse squeegee strokes were incorporated into this experiment. Prior to the experiment, a Gage study was conducted on both the printer inspection system and SPI to ensure measurement repeatability. Results. Based on the R2 value, which is the square of the correlation coefficient, it can be concluded there is a weak correlation between 2-D and 3-D area measurement. Usually, a strong correlation exists when R2 > 90%. With larger pad sizes, we see the correlation is stronger. We also observed the correlation strongly depended not only on pad size, but also aperture shape. However, the 3-D to 2-D area data ratio can change depending on shape; this will be a topic of further study. As predicted, there is an inevitable bias between 2-D and 3-D area measurements, with 2-D consistently measuring a slightly larger area. It should be noted that, for very small pads, the results showed a different trend. As pads get smaller, other effects such as pixel quantization, edge irregularities and the actual size of the solder balls at the edge of the pad begin to affect measurement. We have seen evidence of this phenomenon for much smaller pad size and will report on it in the future. The correlation between 2-D area and volume appears to be stronger than the 2-D area versus 3-D area correlation. Some bimodal structure in the correlegram showed one board possibly having a different print characteristic, a possible investigation for future work. References
Rita Mohanty, Ph.D., is director advanced development at Speedline Technologies (speedlinetech.com); This e-mail address is being protected from spambots. You need JavaScript enabled to view it .
|
Columns
| Semblant Warms to New Fluoropolymer Conformal Coating |
|
Months after hinting at a new conformal coating during a paper session at SMTA International, Semblant has officially launched PlasmaShield. CIRCUITS ASSEMBLY editor in chief Mike Buetow spoke with vice president of worldwide sales and marketing Steve McClure last week. |
| Read more... |
| ECTC in Las Vegas |
What happens in Las Vegas at ECTC, doesn’t stay in Las Vegas, it is shared here. This year’s ECTC, or electronics components technology conference, was held in Las Vegas’ Cosmopolitan, May 28-31. |
| Read more... |
Features
| The Impact of Reel Splicing Kits on Setup and Changeover |
Traditional feeder setup using tape-and-reel can drain time. There’s a quick and better way. |
| Read more... |
| Standard Solar Cells vs. Next-Gen Cells: Which is Winning? |
Overcapacity is stalling the rate of improvement, but only for so long. |
| Read more... |
Products
Viscom Announces SI 7.46 AOI Software Release
Software release SI 7.46 reduces AOI inspection times through improved optimization of travel paths. Integrates Library Manager to assign new inspection patterns more quickly and easily, easing use...
Software release SI 7.46 reduces AOI inspection times through improved optimization of travel paths. Integrates Library Manager to assign new inspection patterns more quickly and easily, easing use...


