DT85M Series 3 Data Logger is for remote monitoring. Features cellular modem. Backlit LCD display shows channel data, alarms, and system status, navigable with six-button keypad. Features temperature operating range of -30°C to 70°C and up to 85% RH. Construction is powder-coated steel and anodized aluminum. Design (peak power 12W) permits use of a smaller solar panel. Enables automatic data delivery. Can send logged data to an FTP server. Internal storage capacity is 128MBs; has removable USB storage device support. Configurable alarm conditions can be used to trigger data delivery and send alarm messages to multiple email addresses or mobile phones. Features 16 analog input channels, expandable up to 320 channels and 960 analog points using optional CEM20 modules, as well as 12 flexible digital channels. Has up to 48 analog sensor inputs with two serial smart sensor ports. Fundamental inputs include voltage, current, resistance and frequency. Supports thermocouples, RTD, thermistors, monolithic temperature sensors, and 4-20mA. Maximum sample speed is 25Hz with 18 bits of effective resolution. Modbus is supported for SCADA connection, as well as multiple SDI-12 interfaces for environmental sensors. dEX graphical interface comes preinstalled.
CAS DataLoggers, www.DataLoggerInc.com