caLogo

Mega SA semiaqueous batch cleaner is designed to use organic solvents requiring a water rinse. Provides 30” x 36” footprint capable of low- to medium-volume defluxing and cleaning. Features 316 stainless steel plumbing and tanks, pneumatic pumps and solenoids, integrated cleanliness verification with pass/fail, fully programmable wash time, rinse time, purity and dry time on touch screen.  Has password-protected maintenance and process setup screens, sealed process with no operator chemical exposure, built-in vent hood and exhaust, onboard transfer pump to sewer/treatment, and 220V 10A power. Options include closed-loop DI system, heater for solvent holding tank, and certified fire suppression system. Custom process tanks are available.

Austin American Technology, www.aat-corp.com


No. 797 260ºF (127ºC), electrically-heated, Class 100 cleanroom cabinet oven is for drying coatings on printed circuit boards. Dimensions: 36” W x 36” D x 39” H. 20 kW are installed in Incoloy-sheathed tubular elements to heat the oven chamber, while a 1000cfm, 1.5hp recirculating blower provides horizontal airflow to the workload. Features 4” insulated walls, Type 304, 2B finish stainless steel interior with continuously back-welded seams, exterior finished with white epoxy paint, #4 brushed stainless steel door cover and control panel face, 30” x 24” x 6” thick stainless steel high-temperature HEPA recirculating filter, plus all safety equipment for handling flammable solvents, including explosion-venting door hardware. Controls include digital indicating, programming temperature controller and SCR power controller.

The Grieve Corp., www.grievecorp.com

Grieve 797web

HeatShieldGel is a water-based gel that protects electronic components from heat. Apply on parts neighboring device to be reworked or on heat-sensitive devices such as ceramic capacitors subject to reflow. Can be used on boards with tightly spaced components without cutting or modification of shielding tape or materials. Reportedly does not impact reliability of the printed circuit board. Is reportedly 4x more effective than Kapton tape. Is a single-use water-soluble clay-based environmentally-safe formula. Is nonflammable, non-toxic and does not have corrosive properties. Clean using DI water and a soft brush or run it through wash machine cycle using a water-only cleaning process. Comes in 3oz plastic sealed screw top jar.

BEST, www.solder.net

 

Pure A4 Sleeve Protector provides barrier protection to shield a person and garment from hazardous chemicals and biologics. Reduces risk of exposure and contamination. Is for situations where full coverage isn’t required. Features include reinforced seams, barrier fabric to provide protection against dangerous liquids, a range of sizes, and thumb loops for full wrist coverage.

Kimtech, www.kimtech.com  

 

Mega Ion solvent cleaning system is compatible with DI water, water alcohol mixtures, pure alcohol, evaporative hydrocarbons (like cyclohexane), commercial solvent blends (like Axarel 2200) and vapor degreasing solvents like (TCE or NPB). Wash and rinse cycles incorporate a spray under immersion process with strategically located venturi nozzles for cleaning efficiency. Agitation can be controlled to handle sensitive wire-bonded substrates or difficult to clean, tightly-spaced flip chip technology. Process chamber is always empty when not in use and must be closed and latched before cleaning cycle begins. for added safety. Automated solvent replenishment ensures operator is never in contact with wash fluid during normal operation. Process tank drains to integrated holding tank at a controlled rate to minimize drag-out. Ionic testing is based on ROSE, for quantifying ionic contamination of the circuit board after or before cleaning. Unique regeneration system increases bath life by removing flux, finger soils and other manufacturing soils from the wash solution without heat or condensing coils. Is said to maintain solvent purity levels at a higher standard than the solvent as received from vendor. Closed-loop environment with wash bath life maintained through the use of an integrated ionic exchange filter system. Provides “Pass or Fail” indication for IPC J-STD cleanliness limits for finished assemblies.

Austin American Technology, aat-corp.com

SSA3000X digital spectrum analyzers include two models with frequency ranges from 9kHz to 2.1GHz and 9kHz to 3.2GHz, respectively. They incorporate all-digital Intermediate Frequency technology. With IF technology, frequency conversion and filtering are accomplished with digital signal processing. Include a 10.1" 1024 x 600 resolution WVGA display. Minimum resolution bandwidth (RBW) is 10Hz; average noise level displayed is -161 dBm/Hz; offset phase noise is -98 dBc/Hz @10 kHz, and total amplitude accuracy is < 0.7 dB. Initial calibration accuracy is < 0.2 ppm. Options include tracking generator, advanced measurement package, EMI measurement function with quasi-peak detection, and reflection measurement kit.

Siglent Technologies America, www.siglentamerica.com

 

Page 315 of 997